air conditioner heat and cool working explain with 4 way valve | 4 way valve explain with diagram
Air conditioner heat and cool explain with 4 way valve and 4 way valve explain with diagram
#electrical #rac #hvac
diagram link : bit.ly/2JaK9Mf
#electrical #rac #hvac
diagram link : bit.ly/2JaK9Mf
Просмотров: 281
Видео
Haier AC tripping problems solved in Urdu and Hindi
Просмотров 1727 часов назад
Haier AC tripping problems solved in Urdu and Hindi
Fridge compressor relay test in Urdu and Hindi | How to check Fridge compressor relay
Просмотров 22714 часов назад
Fridge compressor relay test in Urdu and Hindi | How to check Fridge compressor relay #refrigeratorRepair #hvac #RAC @mitechnicalinstitute @fully4world
Split AC Evaporator leaking protection tip
Просмотров 23714 дней назад
Cooling coil leaking protection tips Electrical functions
Trace AC Gas leakage point Best Way
Просмотров 6342 месяца назад
How to find air conditioner evaporator leakage easy trick
Electrolux Split ac choking problem solved and top reason
Просмотров 1,1 тыс.9 месяцев назад
How to test ac why not cool properly Ac choking problem test and repair ac
Split ac rotary compressor back pressure problem solve
Просмотров 3,6 тыс.9 месяцев назад
Easy to clear fault ac rotary compressor pressure problem Air conditioner outdoor unit big fault solve AC compressor back pressure problem reasonand solution
LG AC indoor PCB Board Not Working How to Test And Solve Fault
Просмотров 1 тыс.10 месяцев назад
Pcb repairing non inverter ac indoor unit pcb card Electrical functions
Split ac outdoor not working how to test & repair
Просмотров 94811 месяцев назад
Split ac outdoor not working how to test & repair
Inverter ac indoor pcb not on trace fault
Просмотров 997Год назад
Inverter ac indoor pcb not on trace fault
Air conditioner icing on indoor unit coil solve fault in Hindi
Просмотров 688Год назад
How to do solve indoor evaporator icing problem Ac indoor fan not work how to do test Electrical functions
How to repair inverter ac remote
Просмотров 55Год назад
Split inverter air conditioner remote not working how to check and solve fault
Refrigerator Cooling Nhi Krti | Kia Mala Hoga Kaise Check Kre?
Просмотров 850Год назад
Refrigerator cooling problem test How to do solve refrigerator cooling problem Learn about refrigerator cooling not properly working Electrical functions
Gree inverter AC E6 Error Coming Reasons & Solution
Просмотров 3,6 тыс.Год назад
How to do remove E6 Error from inverter ac Gree E6 Error Code in Gree dc inverter ac Electrical functions
Inverter AC indoor unit cooling coil U Bend leaking Reason and best solution
Просмотров 2 тыс.Год назад
Inverter AC indoor unit cooling coil U Bend leaking Reason and best solution
Best And Easy Way Gas Charg in Refrigerator R134a in Hindi/Urdu
Просмотров 1,5 тыс.Год назад
Best And Easy Way Gas Charg in Refrigerator R134a in Hindi/Urdu
Copper pipe leaking | Brazing Copper Pipe
Просмотров 706Год назад
Copper pipe leaking | Brazing Copper Pipe
Home water cooler Not Working | Desi Water 💧 Cooler Cooling Problem
Просмотров 855Год назад
Home water cooler Not Working | Desi Water 💧 Cooler Cooling Problem
AC Long Underground Copper Piping Leakage Test With Nitrogen Pressure Best Way
Просмотров 22 тыс.Год назад
AC Long Underground Copper Piping Leakage Test With Nitrogen Pressure Best Way
Outdoor unit condenser fins press recover trick and Explain fins press side Effect on AC
Просмотров 3,5 тыс.Год назад
Outdoor unit condenser fins press recover trick and Explain fins press side Effect on AC
How to Gas Lock 🔒 Easy way Without any Helper
Просмотров 1,5 тыс.Год назад
How to Gas Lock 🔒 Easy way Without any Helper
10 Hp Motor Not Work | Magnetic contactor Problem
Просмотров 406Год назад
10 Hp Motor Not Work | Magnetic contactor Problem
Refrigerator cooling chamber repair silver brazier In Urdu and Hindi language
Просмотров 1,3 тыс.Год назад
Refrigerator cooling chamber repair silver brazier In Urdu and Hindi language
Window AC Very Loud Sound problem solution
Просмотров 17 тыс.Год назад
Window AC Very Loud Sound problem solution
Inverter AC LED Light Full Digits Not Show fault solution in Urdu and Hindi
Просмотров 1 тыс.Год назад
Inverter AC LED Light Full Digits Not Show fault solution in Urdu and Hindi
Deep Freezer 5 points thermostat connection explain in Urdu & hindi
Просмотров 11 тыс.Год назад
Deep Freezer 5 points thermostat connection explain in Urdu & hindi
Sir ise check kese krte hai kharab ya sahi ka is pe video banaiye
Ok iski video bnata hu
Mera Outdoor Direct ho Gaya ha kya ye Relay short ho Gaye ha isko replace krne se fault door ho jaye ga. Saftey switch on krne se chalna shuro ho jata ha or usi se off hota jab k indoor sirf remote se on off hota ha indoor off bhi ho to b outdoor chalta rehta ha
Check krna pry ga ho sakta Hai outdoor mai contactor lga ho so bi khrab ho Gaya to bi direct ho Jata hai
Ye black button agr free ho jaye to is ka kya matlab hota hai? Kharab ho gya hai ye?
Agr kaam nahi kr Raha to khrab hai
Yar ma be ya Kam Kar ta ho
Good
804❤❤
❤❤❤
804
804❤
804❤
804❤
Thanks alot. Apki video se mera lock problem solve ho gya😊
Mera same ye remote hy. Or bachy se lock ho gya hy? Plz unlock Krny ka tareeka bta dn?
السلام علیکم کمپریسر میں ائل کتنے عرصے بعد چینج کرنا چاہیے
Bhai solution batao
Assalam alaikum Sirf ye confirm kar dein 1/5 ton ac ka sensor 1 ton k ac Mai Laga sakte hain ya nahi dono set Haier key hain Mera sensor ok hai.
Bhi ap ka bohat bohat Sukriya
Hai sir how r u sir Sir pls cemical name pls
Assalam oalikum sir my question is HVAC ki job Pak ma asani sa mil jati ha y nhi ma course kr Raha ho or mechanical ma deploma ha mera pas
HVAC ka Diploma Ho kam se kam 2 years wala or Experience Ho sath practical B phir easy mil jati hai
@@electricalfunctions4753 ap kis company ma kr Raha hai or ap kis city sa ha Mera pas deploma ha mechanical ma Mera Kya nhi ho Sakta
@@electricalfunctions4753 ap sikha hai y kaam
❤❤ good
Thanks
Is it possible this error effects the fan on/off (outer unit), I have this error coming after Ac repair men fixed my unit its Kenwood etech after one day this error appeared and now the ac runs then stops then runs again ???? I had to go out and check if the fan is running but it is not spinning and there is no cooling and I can hear compressor running as well what is the cause of this F1, is it the sensor not running the fan or is it the PCB
F1 error ipm fault or your ac neutral lose
Good
Thanks
Thanks bro
Welcome
Mei suraj
bht nice
Thanks Brother
A Good work ❤
Thank you! 😊
Explain in English
Second channel follow in English Language Channel Name : The great engineer
Hi 0.75. ton. Lg split r22. Kuthan..Presser..rakkekha
R22 mai running pressure 60 se 65 psi he rakhty hai chahy unit 4 ton b ho
Bhai mera carrier superia ka ac hai...usme P0 error ata hai....sirf baarish hone par....mera outdoor chatt par pada hai...kya issue ho skta hai??...pls help
Outdoor pcb mai ipm ka error hai 1 bar outdoor service kr ky or outdoor k coil sensor pipe se bahir nikal k jeck lga rahy phir delho msla hal na ho to outdoor pcb fault
@@electricalfunctions4753 thanks bhai.
Auto ka kam kiya hai AC main
Auto Fan krdy gy to senser fan speed kam zyada khud krta rehta hai zarorat k mutabiq
If the unit been installed already can someone drop it before they can service it
How to unlock
In video
Meri motor 14 amp start le rhi hy jb k buton trip ho jata hy
Motor problem hai ya koi wire
Super 🎉
Thanks all
Bht shandar
Thanks
Buhat shukrya apka 5000 ki bachay hoi sirf 1800 main kit repair kerwa ker khud hi fit ker
Good
Sir PCB OK hay but kuch dair k bad compressor bund ho jata hay. cooling b achi hay. capacitor tou kharab nahi hay. Ya compressor ki lead me carbon ka issue ho sukta hay?
Outdoor supply ager off hoti hai to indoor mai sensor problem hogi agr outdoor supply rehti hai lekin compressor trip hota hai to capacitor wagera
@@electricalfunctions4753 Janab me n compressor ki Jali say Dust saf kia tou F1 ka error remove ho ghia. mtlb compressor ko cooling wali air nahi mil ruhi the Jis ki waja say PCB usay trip kr ruha tha. F1 error show ho ruha tha....
Good
Thanks
Ap n bohat mushkil treeqa say samjhaya hay. only top cover open kurnay say he card ko remove kia ja sukta tha.. Is video ko dakhnay k bad koi himat he nahi kuray ga. AC ka unit open kurnay ki. AC Machanic zaroor khush hoon ghay.
Good morning sir This information video is very use full. I need 1 answer 10k resistance ko direct karenge tho relay chalu horahe but sensor ka value check karko new sensor change karengetho relay nahi chalu horahe iska solution chaiye sir.
10k replace krdo bs
اچھے طریقے سے سمجھایا ہے #👍🇵🇰
Thanks
Bhai hamara Haier ka inverter ac hai uska outdoor ka fan ulta chal raha hai kiya problem hai?
Sir size kya h
Pona ton
दिल्ली में मिलेगा तिलत नगर
Thanks sir❤❤❤❤❤❤❤❤❤❤
It was helpful thanks
Bhae spilled ac k out dor fane me kitny uf ka capacitor hota hy
Ager 1 ton to 25uf 1.5 ton hai to 45uf
33 uf to bahoot kam ha